Troubleshooting
Fault messages on the gas condensing...
Control unit
System characteristics
message
F.448
Burner in a fault state
F.449
Burner in a fault state
F.450
Burner in a fault state
F.451
Burner in a fault state
F.452
Burner in a fault state
F.453
Burner in a fault state
F.454
Burner in a fault state
F.455
Burner in a fault state
F.456
Burner in a fault state
F.457
Burner in a fault state
F.458
Burner locked out
F.461
Burner in a fault state
F.462
Burner in a fault state
130
(cont.)
Cause
Deviation, ionisation cur-
rent signal
Error in scheduled pro-
gram run monitoring
Error in scheduled pro-
gram run monitoring
Error in scheduled pro-
gram run monitoring
Error in scheduled pro-
gram run monitoring
Synchronisation error, se-
quence
Incorrect software version
Error in logical program
run monitoring
System status at system
start
Fan blocked
Internal error
Feedback signal of flue
gas damper connection at
EM-EA1 (electronics mod-
ule DIO) extension input
preventing burner start.
LPG safety valve (sole-
noid valve) at EM-EA1
(electronics module DIO)
extension does not open.
Measures
Check ionisation electrode.
Reset device.
Reset device.
Reset device.
Reset device.
Reset device.
Reset device.
Flash the correct software version
for the burner control unit.
Reset device.
Reset device.
Check impeller for ease of opera-
tion. Replace fan unit if necessary.
Reset device.
Restart heat generator. Unlock de-
vice is necessary.
Check flue gas damper connection
at EM-EA1 (electronics module
DIO) extension.
Reset device.
Check solenoid valve connection
at EM-EA1 (electronics module
DIO) extension.
Reset device.