Viessmann Vitovalor PT2 Installation And Service Instructions For Contractors page 146

Fuel cell based micro chp unit with integral gas condensing boiler and adjacent cylinder module natural gas version
Table of Contents

Advertisement

Troubleshooting
Repairs
(cont.)
Check flow temperature sensor
20
10
8
6
4
2
1
0.8
0.6
0.4
10
30
50
Temperature in °C
Fig. 101 Sensor type: NTC 10 k
146
70
90
110
Ω
1. Disconnect plug
from the extension kit.
?
2. Check the sensor resistance and compare it to the
curve.
In the event of severe deviation replace the sensor.