Table 4-1 LANVIEW LEDs
LED
Color
CPU
Red
Amber
Green
Amber
and
Green
PWR
Off
Amber
Green
Link
Off
Green
State
Solid. System is not fully
functional, or the system
is experiencing a fatal
error.
Solid. Power-up testing
in progress.
Solid. System is fully
functional.
Blinking. Device is
booting.
No power.
Solid. Power system
functional.
Solid. Power supplies are
functioning and are in the
redundant mode.
No link.
No activity or port in
standby. Port enabled or
disabled.
Solid. Port is linked.
Recommended Action
If the LED remains red for several minutes,
the system may have a fatal error. Contact
Enterasys Networks for technical support.
If the LED remains amber for more than
several minutes, contact Enterasys
Networks for technical support.
None.
None.
Ensure chassis has adequate power.
1. Ensure that the power cords are plugged
in correctly and that there is power at the
two power sources.
2. Contact Enterasys Networks for
technical support.
None.
None.
None.
Using LANVIEW
Troubleshooting
4-3