Accessing Control Panel Menu: Dc Stick - Miller Dynasty 280 Series Owner's Manual

Table of Contents

Advertisement

8-3.

Accessing Control Panel Menu: DC Stick

5-3. Accessing Control Panel Menu: DC Stick
2
HF START
Schedule 1
Parameter/Setting Display
[DIG] [30%]
[CARB] [ARC]
OM-253086 Page 18
OM-253086 Page 48
Complete Parts List is available at www.MillerWelds.com
A complete Parts List is available at www.MillerWelds.com
3
4
110A
LIFT ARC
Schedule 2
Or
Arc Force Control*
Description
Controls the amount of additional amperage at low voltage (short arc length) conditions. Adjust the force
of the arc for different joint configurations and electrodes. Range is OFF-100%. Features PRO-SET val-
ues for 6010 and 7018 electrodes.
At one step above DIG's 100%, CARBon ARC Gouging can be selected.
1
1 Menu Button
Press Menu button to cycle through parame-
ters that can be set.
2 Parameter Display
3 Setting Display
4 Amperage Adjustment Control
Rotate Amperage Adjustment control to ad-
just parameter setting.
Parameter automatically returns to am-
perage setting 15 seconds after Amper-
age Adjustment control is inactive.
Amperage Control
Controls the welding amperage output. Limits
the maximum output of a remote amperage
device.
*PRO-SET provides PROfessionally devel-
oped SETtings for the weld process. To use
PRO-SET, press the menu button to display
the parameter and adjust the amperage ad-
justment control until PRO-SET flashes on
the display. PRO-SET flashes one time and
247218-C
reveals the professional setting for the
parameter.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents