6-5.

Accessing User Setup Menu: AC And DC TIG

3-5. Accessing User Setup Menu: AC And DC TIG
2
USER
Parameter/Setting Display
[STRT] [HF]
[STRT] [LIFT]
Parameter/Setting Display
[TUNG] [3/32]
Parameter/Setting Display
[RMT] [STD]
[RMT] [HOLD]
[OUT] [ON]
OM-253086 Page 38
Complete Parts List is available at www.MillerWelds.com
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
Or
Arc Starting Method Selection
Description
Is a non-contact starting method (see Section 15-1).
Is a contact starting method (see Section 15-1).
Tungsten Diameter Selection
Description
Each tungsten size has preset starting parameters specific to that diameter for optimized starting. Range
is 0.020 in. to 1/8 in. or 0.5 mm to 3.2 mm. To manually set starting parameters, see Section 15.
Trigger Mode Selection
Description
Typically used with a remote foot or hand control. RMT STD requires a maintained contact closure to ena-
ble weld output. Amperage can be controlled with a remote potentiometer, or it can be set at the control
panel.
Remote control required. Allows the operator to weld without holding the trigger closed. To start the weld,
operator presses and releases trigger. To stop the weld, the operator again presses and releases the trig-
ger. In this mode, only the output contactor is controlled by the remote control. Amperage must be set on
the control panel.
Output on. (Lift Only)
Weld output terminals are energized at all times when displays read [OUT] [ON].
No remote control or trigger required. Amperage can be controlled at the control panel or with a remote
potentiometer. Blue output on LED illuminates to indicate output is on.
1
1 Menu Button
Press and hold Menu button for approxi-
mately 2 seconds to access machine User
Setup menu. Use Menu button to cycle
through parameters that can be set.
2 Parameter Display
3 Setting Display
4 Amperage Adjustment Control
Rotate Amperage Adjustment control to ad-
just parameter setting.
To exit menu, press and hold Menu but-
ton until Menu Off is displayed.