15-3. General (GEN) Tungsten To Change Programmable TIG Starting Parameters

9-5.
General (GEN) Tungsten Programmable TIG Starting Parameters (DX Models Only)
TUNG
TUNG
Available Parameter Settings
Current (A)
Start Time
Start Slope Time
Parameter
Start Output Polarity (POL)
Start Amperage (STRT)
Start Time (TIME)
Start Slope (SSLP)
Preset Minimum Amperage
(PMIN)
OM-270536 Page 42
OM-253086 Page 74
2
2
GEN
GEN
Preset Amperage Minimum
Default AC
EP (Electrode Positive)
30 A
120 ms
120 ms
10 A
1 Amperage Adjustment Control
2 Parameter Display
3 Amperage Button
Once inside the machine set up menu, tung-
sten parameter values can be manually
1
1
changed by pressing the Amperage switch
pad to step through each adjustable parame-
ter. Rotate encoder to change the value.
3
3
247220-D
Default DC
EN (Electrode Negative)
25 A
120 ms
100 ms
10 A
OM-275857 Page 19
Range
EP / EN
5–200 A
0–250 ms
0–250 ms
1–25 A (DC)
2–25 A (AC)