Accessing Control Panel Menu: Dc Tig - Miller Dynasty 280 Series Owner's Manual

Table of Contents

Advertisement

6-3.

Accessing Control Panel Menu: DC TIG

3-3. Accessing Control Panel Menu: DC TIG
2
3-4. Accessing Control Panel Menu: AC And DC Stick
Parameter/Setting Display
[PPS] [OFF]
2
Parameter/Setting Display
[POST] [AUTO]
OM-253086 Page 36
OM-253086 Page 10
A complete Parts List is available at www.MillerWelds.com
Complete Parts List is available at www.MillerWelds.com
4
3
150A
Pulse Control*
Description
Reduces heat input to minimize distortion and increase travel speed. Set PPS (pulses per second). The
3
4
range is OFF−250 PPS. The Background Amperage and Peak Amperage are not adjustable. Background
Amperage equals 25% of Peak amperage. Peak amperage Time equals 40%.
Post Flow Control
Description
Controls the length of time gas flows after welding stops. Range is AUTO, OFF - 50T (seconds). AUTO
calculates the time based on the maximum amperage of each welding cycle. The minimum time is 8 sec-
110A
onds. Auto = maximum amperage/10.
Or
1 Menu Button
Press Menu button to cycle through parame-
ters that can be set.
1
2 Parameter Display
3 Setting Display
4 Amperage Adjustment Control
Rotate Amperage Adjustment control to ad-
just parameter setting.
Parameter automatically returns to am-
perage setting 15 seconds after Amper-
age Adjustment control is inactive.
Amperage Control
Controls the welding amperage output. Limits
the maximum output of a remote amperage
device.
*PRO-SET provides PROfessionally devel-
oped SETtings for the weld process. To use
PRO-SET, press the menu button to display
the parameter and adjust the amperage ad-
justment control until PRO-SET flashes on
the display. PRO-SET flashes one time and
reveals the professional setting for the
247222-D
parameter.
1
247222-D

Hide quick links:

Advertisement

Table of Contents
loading