11-4. Voltmeter/Ammeter Display Messages

All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit.
Message Type
Release Trigger
Un Short Output
Over Temperature Error
Latching Error
Not Valid
Lock Level
Software Not Valid
Complete Parts List is available at www.MillerWelds.com
Display Message
[RELE] [ASE] /
[TRIG] [GER]
[UN S] [HORT] /
[OUTP] [UT]
[OVER] [TEMP]
When one of the following errors occurs, the Standby LED flashes. To clear error, press Standby button or turn
off power. See Section 11-5 if error does not clear or happens frequently.
[CHEK] [INPT]
[WELD] [CABL]
[SEE] [O.M.]
[COOL] [PWR]
[NOT] [VALD]
[LOCK] [LEV1]
[SOFT] [WARE] /
[NOT] [VALD]
Description
Remote 14 receptacle contactor control (Pins A-B) must be opened before
proceeding.
Short on weld output connections must be removed before proceeding. See
Section 11-5if display shows after weld output connections have been verified
as not having a short.
Over temperature condition has occurred. Error will clear after temperatures
reach acceptable levels.
Check Input: High or low voltage has been sensed. Have a qualified person
check input voltage.
Weld Cable: An error related to the weld cables has been sensed. Straighten
out or shorten weld cables. If Carbon arc gouging, adjust DIG setting to Car-
bon ARC.
See Owner's Manual: See Section 11-5.
Cooler Power: An error related to the CoolMate 1.3 Power has occurred.
When error will not clear or occurs frequently, cooler can be plugged into a
nearby 115 volt AC receptacle, or machine can be used without the Cooler
Power, turn Cooler Power off.
Message is displayed when attempting an incompatible setup; i.e., pressing
AC Waveshape while in DC.
Is displayed when attempting adjustments that are incompatible with the ac-
tive selected lock level.
A software compatibility error has been detected. A software update is re-
quired (see Section 5-12). See Section 11-5 if display shows after a software
update is performed.
OM-253086 Page 65