SECTION 10 – ADVANCED MENU FUNCTIONS
SECTION 7

10-1. Accessing Tech Menu For Dynasty/Maxstar 280 Models

7-1. Accessing Tech Menu For Dynasty/Maxstar 280 Models
2
TECH
Parameter/Setting Display
[ARC] [T/CY]
[ERR] [LOG]
[SLEP] [OFF]
[STUC] [OFF]
[OCV] [NORM]
[COOL] [AUTO]
[MACH] [RSET]
[SOFT] [WARE]
[SERL] [NUM]
OM-253086 Page 24
Complete Parts List is available at www.MillerWelds.com
A complete Parts List is available at www.MillerWelds.com
ADVANCED MENU FUNCTIONS
3
4
MENU
Description
Arc Timer: Monitors hours, minutes, and cycles of valid arc on. To view, rotate amperage adjustment con-
trol. To reset, rotate amperage adjustment control until [RESET] [YES] is displayed. Press Menu button to
display [RESET] [Done]. Displays turn to [000] [000].
Error Log: Use to view last eight logged error events. Each event may list multiple Error Codes. See Sec-
tion 11-5.
Sleep Timer: Turns power off after the machine exceeds the programmed idle time without operation.
Press the Standby button to turn power on. To set or change time, rotate amperage adjustment control to
desired time. Timer range: 1, 5, 10, 20, 30, 45 minutes or one hour.
Stick Stuck: Detects if the electrode is stuck or shorted to the workpiece. Turns weld output off to aid in
freeing the electrode. To turn on, rotate amperage adjustment control. Not recommended for air carbon
arc or large diameter electrodes.
Open Circuit Voltage: Allows user to select between Normal [NORM] and Low open circuit voltage. Low
reduces open circuit voltage to between 8 and 15 volts. To select, turn amperage adjustment control.
Cooler Power (Optional): Selects between [OFF], [ON] (Non CE models Only), and [AUTO]. [OFF] dis-
ables the power supply to the receptacle. [ON] enables the power supply to the receptacle. [AUTO] pro-
vides power to the receptacle when the TIG process is active.
Machine Reset: Resets all machine values back to factory defaults. To reset, turn amperage adjustment
control to [RESET] [YES]. Then press Menu button. [RESET] [DONE] will be displayed when the reset is
complete and factory defaults have been restored.
Software Number: Software number and revision will be displayed.
Serial Number: If serial number displayed does not match serial number of machine, see Section 11-5
1
1 Menu Button
Press and hold Menu button for approxi-
mately four seconds to scroll past User Menu
to Tech Menu. Use Menu button to cycle
through parameters that can be set.
2 Parameter Display
3 Setting Display
4 Amperage Adjustment Control
Rotate amperage adjustment control to ad-
just parameter setting.
Dynasty 280 shown. Maxstar menus
are the same. Menu order may vary.
To exit tech menu, press and hold menu but-
ton approximately one second, or turn power
off.
Settings in the Tech Menu are global,
meaning they may pertain to all or some
of the process.
247222-D