3. Remove the injectors and replace with the corresponding injector
as shown in the table at the bottom of this page.
Setting up minimum flow rates:
1. Remove the control knobs.
2. Turn on the LPG supply,
light the burners and turn
the controls to the minimum
position, as indicated by the
small flame.
3. Insert a 2.5mm screwdriver
into the hole at the top of the
tap and turn the adjustment screw fully clockwise as shown in fig. 5.
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.

LPG to Natural Gas Conversion

This hob can be converted from propane operation at a nominal inlet
pressure of 37mbar or butane operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar. This conversion must only be
carried out by a competent person (i.e. a Gas Safe registered fitter).
SOMIPRESS burner. (indicated "SOMIPRESS." on the burner body)
G20 2H 20 mbar
G30/31 3+ 28-30/37 mbar
IMPORTANT: ONCE CONVERTED, REMEMBER TO LABEL THE
HOB, AS PER THE GAS TYPE, ACCORDINGLY.
Type of gas
Fig. 5
Burner
auxiliary
medium
0,72
0,98
0,52
0,67
large
1,17
0,83