3. Remove the injectors and replace with the corresponding injector
as shown in the table at the bottom of this page.
Setting up minimum flow rates:
1. Turn on the gas supply, light
the burners and turn the
controls to the minimum
position, as indicated by the
small flame.
2. Remove the control knobs.
3. Insert a 2.5mm screwdriver
into the slit as shown in Fig.5,
and turn the adjustment screw fully clockwise.
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.

LPG to Natural Gas Conversion

This hob can be converted from propane operation at a nominal inlet
pressure of 37mbar or butane operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar. This conversion must only be
carried out by a competent person (i.e. a Gas Safe registered fitter).
SOMIPRESS burner. (indicated "SOMIPRESS." on the burner body)
G20 2H 20 mbar
G30/31 3+ 28-30/37 mbar
IMPORTANT: ONCE CONVERTED, REMEMBER TO LABEL THE
HOB, AS PER THE GAS TYPE, ACCORDINGLY.
Type of gas
Fig. 5
Burner
auxiliary
medium
0,76
0,98
0,52
0,70
ultra large
1,33
1,00
19