Ventilation

All rooms require a window, or equivalent (e.g. a door), which can
be opened. Some rooms require a permanent vent in addition to a
window (see below).
This unit must not be used in a room which is less than 5m³. The
following table details the requirements based on the kitchen
volume (DxWxH) in m³.
The above requirements also allow for use of a gas oven and
grill. However, if there are any other fuel burning appliances in the
same room, consult the relevant British Standard (BS5440) or GAS
SAFE Document.

Natural Gas to LPG Conversion

This hob can be converted from natural gas to propane operation
at a nominal inlet pressure of 37mbar, or butane operation at a
nominal inlet pressure of 28/30mbar. This conversion must only be
carried out by a competent person (i.e. a Gas Safe registered fitter).
Instructions to fit replacement injectors:
1. Disconnect the appliance from the
gas and electrical supplies.
2. Remove burner components and pan
supports.
18
Tools/parts required:
• 7mm AF nut spinner
• Replacement injectors
• LPG identity plate