Mains electrical
connection
Warning! This appliance must be
earthed.
This appliance is intended to be
connected to fixed wiring by a double
pole switch, having a contact separation of at least 3mm in all
poles and protected by a 13A fuse. The switch must be positioned
no further than 2m from the appliance.
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will comply
with the I.E.T and local regulations. The wires in the mains lead are
coloured in accordance with the following code:
GREEN AND YELLOW = EARTH BLUE = NEUTRAL BROWN =
LIVE.
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals in
your spur box, proceed as follows:
1. The wire which is coloured green and yellow must be connected to
the terminal marked E (Earth) or coloured Green.
2. The wire which is coloured blue must be connected to the terminal
marked N (Neutral) or coloured Black.
3. The wire which is coloured brown must be connected to the
terminal marked L (Live) or coloured Red.
DOUBLE POLE
SWITCHED
FUSE SPUR OUTLET
13A