4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.
LPG to Natural Gas
Conversion
This hob can be converted from
propane operation at a nominal
inlet pressure of 37mbar or butane
operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar.
This conversion must only be carried
out by a competent person (i.e. a Gas
Safe registered fitter).
Burner
Rapid
Semi-Rapid
Auxiliary
Triple ring/Wok
14
LPG Injector
86
67
49
100
Required:
7mm AF nut spinner
Replacement injectors
NG identity plate
Natural Gas Injector
115
97
72
135