CDA HG7250 Installation, Use And Maintenance Instruction

Advertisement

Quick Links

HG7250,
HG7350 &
HG9350
Gas Hobs
Installation, Use and Maintenance
Customer Care Department • The
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu
www.cda.eu

Advertisement

Table of Contents
loading

Summary of Contents for CDA HG7250

  • Page 1 Gas Hobs Installation, Use and Maintenance Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu www.cda.eu...
  • Page 2 Important Make sure that this instruction booklet is read thoroughly and understood before attempting to install or operate this hob. The instructions are provided in the interest of your safety. The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.
  • Page 3 Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance Model...
  • Page 4 Parts intended to come into contact with food conform to 1935/2004/ IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EU DIRECTIVE 2012/19/EC. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
  • Page 5: Using Your Hob

    • This hob (Class 3) has been designed for use only as a cooking appliance. Any other use (e.g. heating rooms) should be considered incorrect and potentially dangerous. • These instructions are valid only for the countries of destination, the symbols of which appear the appliance.
  • Page 6 HG7250 & HG7350 Fig. 2 HG9350 Fig. 3...
  • Page 7 Key to Fig 2 Gas burners: 1. Triple burner 3.8kW 2. Rapid burner 3.0kW 3. Semi-Rapid burner 1.75kW 4. Auxiliary burner 1.0kW Control panel: 5. Front left burner control knob 6. Back left burner control knob 7. Centre burner control knob 8.
  • Page 8: Igniting The Burners

    Igniting the Burners The hob is fitted with a flame failure device. Flame failure devices operate by shutting off the supply of gas to the burner in the event that the flame is extinguished accidentally. Fig. 4 To ignite the burners, follow these instructions: 1.
  • Page 9: Efficient Use Of Your Hob

    Efficient Use of Your Hob The hob is equipped with burners of different sizes, designed to accommodate most shapes and sizes of pan. For best results, only use pans with flat bottoms and choose an appropriate burner depending on the size of the pan. The most efficient use of the hob is shown below, where the pan and burner are correctly chosen.
  • Page 10 Correct Use of the Wok Pan Adaptor The wok pan adaptor is a special stand that is designed to be fitted over the triple ring burner to give support to round bottomed woks. When using a wok, always place the wok pan adaptor in position over the pan support on the triple ring burner as shown in Fig.6.
  • Page 11: Care And Maintenance

    Care and Maintenance As the hob has a stainless steel or enamel surface, you should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. Stainless steel can be effectively cleaned by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.
  • Page 12 Burner Size Nominal Rating Simmer Rating LPG Flow Rate (lh (kW) (kW) Auxiliary 72.8 71.5 Semi-Rapid 1.75 134.6 132.2 Rapid 218.8 214.8 Triple / Wok Total rated gas input : 11.3kW Mains electrical voltage: 230 – 240Vac, 50Hz Total rated electrical consumption: If Your Hob is Not Working 1.
  • Page 13: Mains Electricity Connection

    Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE. DOUBLE POLE SWITCHED We recommend that the appliance is FUSE SPUR OUTLET connected by a qualified electrician, who is a member of the N.I.C.E.I.C.
  • Page 14: Gas Supply Requirements

    UK and Ireland. The installation must comply with the Gas Safety (installation and use) Regulations 1984. • The CDA Group Ltd is not legally able to provide any assistance in the installation of gas appliances except to Gas Safe registered installers.
  • Page 15 Ventilation All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in addition to a win- dow (see below). This unit must not be used in a room which is less than 5m .
  • Page 16: Natural Gas To Lpg Conversion

    Natural Gas to LPG Conversion This hob can be converted from natural Required: gas to propane operation at a nominal • 7mm AF nut spinner inlet pressure of 37mbar, or butane • Replacement injectors • LPG identity plate operation at a nominal inlet pressure of 28/30mbar.
  • Page 17 LPG to Natural Gas Conversion Required: • 7mm AF nut spinner This hob can be converted from • Replacement injectors propane operation at a nominal • NG identity plate inlet pressure of 37mbar or butane operation at a nominal inlet pressure of 28/30mbar to natural gas at 20mbar.
  • Page 18: Fitting The Hob

    Fitting the Hob Unpacking the hob: Take care not to lose or mishandle any parts. Fitting position of the hob: This appliance must be installed in accordance with the dimensions in Fig. 11 on page 21 of this manual and a minimum of 150mm away from any adjacent vertical surfaces, e.g.
  • Page 19 • This appliance is designed to be installed into cabinet units capable of withstanding temperatures 65°C above ambient or greater (typically 80-90°C). • The rear wall or splashback the hob is to be fitted in front of must be made of flame resitant material •...
  • Page 20: How To Install The Hob

    How to Install the Hob Installation Dimensions (mm) HG7250 & HG9350 HG7350 Overall width Overall depth Worktop cutout width Worktop cutout depth 1. Make the required hole in the worktop. Note that before doing this, check the instructions supplied with any cooker hood to ensure that you will have the required clearance.
  • Page 21 >50mm 477mm HG7250 & HG9350 HG7350 Cutout width (W) 557mm 832mm Landing (L) 210mm 165mm Fig. 12 Fig. 11 Fig. 13 Fig. 14...
  • Page 22: Energy Efficiency Information

    Energy Efficiency Information A) Measurement and calculation methods • The gas hob was CE approval according to the Gas Appliance Directives 2009/142/EC. • The energy efficiency of this gas hob was tested and measured according to EN 30-2-1-1998+A1-2003+A2-2005. • The semi-rapid burner and rapid burner were tested separately; the auxiliary burner is not required for test because its nominal heat input is less than 1.16kW.
  • Page 23 56.0 56.0 Gas hob PIN Number HG7250 HG7350 HG9350 2531CT-0054 2531CT-0054 2531CT-0054 2531-18 Country of destination:GB/IE E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
  • Page 24 Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.eu www.cda.eu...

This manual is also suitable for:

Hg7350Hg9350Hg7350ssHg7250blHg9350ss

Table of Contents