Lpg To Natural Gas Conversion - CDA HVG980 Directions For Installation, Use And Maintenance

Five burner gas hob
Table of Contents

Advertisement

3. Remove the injectors and replace with the corresponding injector
as shown in the table at the bottom of this page.
Setting up minimum flow rates:
1. Turn on the gas supply, light
the burners and turn the
controls to the minimum
position, as indicated by the
small flame.
2. Remove the control knobs.
3. Insert a 2.5mm screwdriver
into the slit as shown in Fig.5,
and turn the adjustment screw fully clockwise.
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.

LPG to Natural Gas Conversion

This hob can be converted from propane operation at a nominal inlet
pressure of 37mbar or butane operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar. This conversion must only be
carried out by a competent person (i.e. a Gas Safe registered fitter).
SOMIPRESS burner. (indicated "SOMIPRESS." on the burner body)
Type of gas
G20 2H 20 mbar
G30/31 3+ 28-30/37 mbar
IMPORTANT: ONCE CONVERTED, REMEMBER TO LABEL THE
HOB, AS PER THE GAS TYPE, ACCORDINGLY.
Fig. 5
auxiliary
medium
0,76
0,98
0,52
0,70
Burner
large
1,17
0,86
ultra large
1,33
1,00
19

Advertisement

Table of Contents
loading

Table of Contents