6.36.4 Changing the standard monitor display

 : Standard monitor display selection
 ~  : Status monitor 1~8 display selection
These parameters are used to select the item to be displayed when the power turned on and also to change items
displayed in status monitor mode.
⇒ For details, refer to Section 8.3.

6.36.5 Canceling the operation command

 : Operation command clear selection when standby terminal (ST) is OFF
• Function
When the standby (ST) terminal is turned off during panel operation, the inverter will restart operation if the
ST terminal is turned back on. Using this parameter, you can also set the inverter so that, even if the ST is
turned back on, it will not restart operation until you press the RUN key.
Title


6.36.6 Selection of operation panel stop pattern

 : Operation panel stop pattern selection
6
• Function
This parameter are used to select a mode in which the motor started by pressing the RUN key on the
operation panel is stopped when the STOP key is pressed.
1) Deceleration stop
The motor stops in the deceleration time set with the parameter  (or , ).
2) Coast stop
The output of the inverter is cut off. The motor comes to a stop after coasting for a while by inertia. Depending on
the load, the motor may keep running for a good long time.
[Parameter setting]
Title


6.36.7 Setting of a torque command in panel operation mode

 : Operation panel torque command (reference value in %)
• Function
This parameter allows you to set a torque command value when torque is controlled with the operation
panel.
Note: This parameter is operative only when , ,  and  are set to . The value
set with this parameter is used as the command value (%) for each function.
Operation panel operation: Torque command selection  is set at  (Panel input).
[Parameter setting]
Title

⇒ For details refer to the Instruction Manual (xxxxxxxx) for this parameter.
Function
Operation command clear selection
when standby terminal (ST) is OFF
Function
Parameter stop pattern selection
Function
Operation panel torque command
Adjustment range
:Clear operation command
:Retain operation command
Adjustment range
:Deceleration stop
:Coasting
Adjustment range
-~%
F-70
E6581301
Default setting
Default setting
Default setting