6.31.4 Changing the standard monitor display

 : Standard monitor display selection
 ~  : Status monitor 1~4 display selection
These parameters are used to select the item to be displayed when the power turned on and also to change items
displayed in status monitor mode.
 For details, refer to Section 8.3.

6.31.5 Selection of operation panel stop pattern

 : Operation panel stop pattern selection
 Function
This parameter are used to select a mode in which the motor started by pressing the RUN key on the
operation panel is stopped when the STOP key is pressed.
1) Deceleration stop
The motor stops in the deceleration time set with the parameter  (or ).
2) Coast stop
The output of the inverter is cut off. The motor comes to a stop after coasting for a while by inertia. Depending on
the load, the motor may keep running for a good long time.
[Parameter setting]
Title

6
6.32

Tracing functions

 : Trace selection
 : Trace cycle
 : Trace data 1
 Function
These parameters are used to memorize and read out the data collected at the time of tripping or triggering.
Up to 4 kinds of data can be selected from 64 kinds of data, and the data collected at 100 consecutive
points can be stored in memory as trace data.
Here is the time at which trace data is acquired.
 Tripping: Data collected before the occurrence
 Triggering: Data collected after triggering
Note: To read data on a PC.
Title






(Note1): For saving trace data, do not disconnect the control power supply or the main circuit power supply during
15 second after inverter tripped.
(Note2): When  =  or  setting, set the value of  (Constant at the time of filtering) lower than
 setting time (trace cycle time).
Function
Operation panel stop pattern selection
Function
Trace selection
Trace cycle
Trace data 1
Trace data 2
Trace data 3
Trace data 4
Adjustment range
:Deceleration stop
:Coast stop
 : Trace data 2
 : Trace data 3
 : Trace data 4
Adjustment range
 :Deselect 
 :At tripping 
 :At triggering
 :4ms
 :20ms
 :100ms
 :1s
 :10s 
 ~ 
 ~ 
 ~ 
 ~ 
F-68
E6581386
Default setting

Default setting





