[23] Acceleration/deceleration 2 [2/2]
Communi
Title
cation
Function
No.
0514
Acceleration time 4
f514
0515
Deceleration time 4
f515
Acceleration/ deceleration 4
f516
0516
pattern
Acceleration/deceleration
f517
0517
switching frequency 3
*1: Default values vary depending on the capacity. ⇒ See the table of K-46.
*2: Changing the parameter  enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
[24] Pattern operation [1/3]
Communi
Title
cation
Function
No.
0520
Pattern operation selection
f520
0521
Pattern operation mode
f521
Number of repetitions of pattern
0522
f522
group 1
f523
0523
Pattern group 1 selection 1
0524
Pattern group 1 selection 2
f524
f525
0525
Pattern group 1 selection 3
f526
0526
Pattern group 1 selection 4
0527
Pattern group 1 selection 5
f527
f528
0528
Pattern group 1 selection 6
f529
0529
Pattern group 1 selection 7
0530
Pattern group 1 selection 8
f530
Number of repetitions of pattern
f531
0531
group 2
0532
Pattern group 2 selection 1
f532
f533
0533
Pattern group 2 selection 2
0534
Pattern group 2 selection 3
f534
0535
Pattern group 2 selection 4
f535
f536
0536
Pattern group 2 selection 5
0537
Pattern group 2 selection 6
f537
0538
Pattern group 2 selection 7
f538
f539
0539
Pattern group 2 selection 8
Adjustment range
0.1~6000 sec.
0.1~6000 sec.
0:Straight, 1:S-pattern 1, 2:S-pattern 2
0.0~ Hz
Adjustment range
0:Deselect
1:Select (setting in units of seconds)
2:Select (setting in units of minutes)
0:Pattern operation reset when system stops
operation
1:Pattern operation continued even after system
stops operation
1~254, 255:∞
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
1~254, 255:∞
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
1
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
1
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
PM
V/f Constant Reference
Torque
control
control
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
PM
V/f Constant Reference
Torque
control
control
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31

Hide quick links: