[29] Communication function [3/4]
Communi
Title
cation
Function
No.
Communication option
0845
f845
(DeviceNet/Profibus) setting 12
Communication option
0846
f846
(DeviceNet/Profibus) setting 13
Disconnection detection
0850
f850
extended time
Inverter operation at
0851
f851
disconnection
Preset speed operation
f852
0852
selection
Communication option station
f853
0853
address monitor
Communication option speed
f854
0854
switch monitor
Device Net/CC-Link
Communication option data
f855
0855
swap selection
f870
0870
Block write data 1
f871
0871
Block write data 2
*1: ⇒ Refer to the instruction manual (xxxxxxxx or xxxxxxxx) for the optional DeviceNet/Profibus communications device.
*2: ⇒ Refer to the instruction manual (xxxxxxxx, xxxxxxxx or xxxxxxxx) for the optional communications device used.
Adjustment range
0000~
0000~
0.0~100.0 sec.
0:Inverter stop, communication command,
frequency mode open (by CMOD, FMOD)
1:None (continued operation)
2:Deceleration stop
3:Coast stop
4:Emergency stop (E trip)
5:Preset speed operation (by  setting)
0:None
1~15:Preset speed operation (by parameter
setting)
0~254
0~255
0~1
0:Deselect
1:Command information 1
2:Command information 2
3:Frequency command
4:Terminal board output data
5:Communication analog data
Ditto
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
*1
●/●
*1
●/●
6. 38. 1
●/●
6. 38. 1
●/●
6. 38. 1
●/●
*2
●/●
*2
●/●
*2
●/●
6. 38. 1
●/●
6. 38. 1