Toshiba TOSVERT VF-AS1 Instruction Manual page 243

The new generation high-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[21] Torque limit [2/2]
Communi
Title
cation
Function
No.
Regenerative braking torque
0443
f443
limit 1 level
Power running torque limit 2
0444
f444
level
Regenerative braking torque
f445
0445
limit 2 level
Power running torque limit 3
f446
0446
level
Regenerative braking torque
f447
0447
limit 3 level
Power running torque limit 4
f448
0448
level
Regenerative braking torque
0449
f449
limit 4 level
Acceleration/deceleration
0451
f451
operation after torque limit
Power running stall continuous
0452
f452
trip detection time
Regenerative braking stall
f453
0453
prevention mode selection
[22] Adjustment parameters [1/2]
Communi
Title
cation
Function
No.
0458
Current control proportional gain 0.0~100.0
f458
0460
Speed loop proportional gain
f460
Speed loop stabilization
f461
0461
coefficient
f462
0462
Moment of inertia of load 1
f463
0463
Second speed loop proportional gain 1~9999
Second speed loop stabilization
0464
f464
coefficient
f465
0465
Moment of inertia of load 2
0466
Speed PI switching frequency
f466
f470
0470
VI/II input bias
f471
0471
VI/II input gain
f472
0472
RR/S4 input bias
0473
RR/S4 input gain
f473
f474
0474
RX input bias
f475
0475
RX input gain
0476
A1 input bias
f476
f477
0477
A1 input gain
*1: ⇒ For details refer to the Instruction Manual (xxxxxxxx) for this parameter.
*2: ⇒ Settings vary from unit to unit. Even if  is set to , no change is made to these values.
Adjustment range
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0.0~249.9%, 250.0%:Disabled
0:In sync with acceleration/deceleration
1:In sync with min. time
0.0~1.0 sec.
0:Stall during regenerative braking
1:Not stall during regenerative braking
Adjustment range
1~9999
1~9999
0~100
1~9999
0~100
0.0~ Hz
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.1/0.1
0.0
Enabled
●/●
1/1
40
Enabled
●/●
1/1
100
Enabled
●/●
1/1
35
Enabled
●/●
1/1
40
Enabled
●/●
1/1
100
Enabled
●/●
1/1
35
Enabled
●/●
1/1
0.0
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
1/1
*2
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
6. 25. 1
●/●
6. 25. 1
●/●
6. 25. 1
●/●
6. 25. 1
●/●
6. 25. 1
●/●
6. 25. 1
●/●
6. 25. 1
-
6. 25. 2
-
6. 26. 1
-
6. 26. 2
PM
V/f Constant Reference
Torque
control
control
●/●
-
-
*1
-
-
-
*1
-
-
-
*1
-
-
*1
-
-
-
*1
-
-
*1
-
-
*1
-
-
-
*1
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents