Connect the other end of the cable to the front of the I/O breakout panel.
Spring latch
Note: Ensure the spring latches are fastened.
3
If ELAN is present, connect the ELAN cable to the RJ-45 outlet on the left
(connector 1).
Note: You must use a shielded twisted pair cable.
4
Connect the other end of the ELAN cable to your ELAN hub.
5
If you have a CLAN adapter installed, connect the CLAN cable to the RJ-45
outlet on the right (connector 2).
Note: You must use a shielded twisted pair cable. When the CLAN card is
installed on your 200i server, the COM2 port is unavailable. COM2 is
currently reserved for future use.
6
Connect the other end of the CLAN cable to your CLAN network hub
(10Base-T compliance) or Token Ring MAU, router, or bridge.
.
Part 2: 200i Server Hardware Installation
CAUTION
Risk of fire hazard if MAU is installed in an improper location
MAUs are not suitable for installation in ducts, plenums or other
spaces used for environmental air. Do not install above a false
ceiling or below a raised floor, unless it can be confirmed that
these spaces are not used to convey environmental air.
Installing the server, cables, and peripheral devices
Spring latch