26/69
Bosch Rexroth AG
Dimensions
6.4
Installation
6.4.1
Installation notes
6.4.2
Mounting cut-out
6.4.3
Mounting dimensions VAM 10.2
Rexroth IndraControl VAM 10.2/40.2 Machine Control Panels
●
When installing the control panel, ensure an ergonomic operation. Addi‐
tionally, ensure that all moving machine components can be seen by the
operator at any time
●
Avoid installation locations exposed to direct sunlight, as additional heat
development can occur.
●
When installing the control panel, ensure an easy access to the front
panel (top side).
●
Ensure that the LED displays are visible on the front panel
●
Provide a sufficient minimum clearance of 50 mm for cooling and cable
routing behind the device
●
Lay all connecting cables in loops and use strain reliefs for all cables
●
Keep as much distance as possible to noise sources
To mount the control panel, proceed as described in the following:
1. Create a mounting cut-out with 6 drilled holes and a cross-section of 4.5
mm as described in
26
and
fig. 6-10 "Mounting dimensions VAM 40.2" on page
2. Insert the control panel from the front into the cut-out. Then, insert the
mounting bolts M4 into the drilled holes.
3. Fasten the control panel by screwing the nuts on the rear side of the
mounting bolts.
Hole for threaded bolt
1 6 9 1 5 4
7,5
7,5
Fig. 6-9:
Mounting dimensions VAM 10.2
DOK-SUPPL*-VAM*XX.2***-PR03-EN-P
fig. 6-9 "Mounting dimensions VAM 10.2" on page
Mounting cut-out
141 x 322
1 6 7 ,5
3 5 0
27.
1 6 7 ,5