Installation; Installation Notes; Mounting Cut-Out; Mounting Dimensions Vam 10.2 - Bosch Rexroth VAM 10.2 Project Planning Manual

Machine control panels
Table of Contents

Advertisement

26/69
Bosch Rexroth AG
Dimensions
6.4

Installation

6.4.1

Installation notes

6.4.2

Mounting cut-out

6.4.3

Mounting dimensions VAM 10.2

Rexroth IndraControl VAM 10.2/40.2 Machine Control Panels
When installing the control panel, ensure an ergonomic operation. Addi‐
tionally, ensure that all moving machine components can be seen by the
operator at any time
Avoid installation locations exposed to direct sunlight, as additional heat
development can occur.
When installing the control panel, ensure an easy access to the front
panel (top side).
Ensure that the LED displays are visible on the front panel
Provide a sufficient minimum clearance of 50 mm for cooling and cable
routing behind the device
Lay all connecting cables in loops and use strain reliefs for all cables
Keep as much distance as possible to noise sources
To mount the control panel, proceed as described in the following:
1. Create a mounting cut-out with 6 drilled holes and a cross-section of 4.5
mm as described in
26
and
fig. 6-10 "Mounting dimensions VAM 40.2" on page
2. Insert the control panel from the front into the cut-out. Then, insert the
mounting bolts M4 into the drilled holes.
3. Fasten the control panel by screwing the nuts on the rear side of the
mounting bolts.
Hole for threaded bolt
1 6 9 1 5 4
7,5
7,5
Fig. 6-9:
Mounting dimensions VAM 10.2
DOK-SUPPL*-VAM*XX.2***-PR03-EN-P
fig. 6-9 "Mounting dimensions VAM 10.2" on page
Mounting cut-out
141 x 322
1 6 7 ,5
3 5 0
27.
1 6 7 ,5

Hide quick links: