Control panels CP1 and CP2 | Installation
Bosch Rexroth AG, RE 95259-01-B/2021-11-09

7 Installation

Prior to installation, the following documents should be to hand:
• Data sheet of the product (contains the permissible technical data,
main dimensions and circuit diagrams of standard versions)
7�1 Unpacking
NOTICE! Danger due to electrostatic discharge!
When unpacking the control panel, there is a danger of damage to the electronic
components of the control panel due to electrostatic discharge.
▶ When unpacking, protect the control panel against electrostatic discharge;
information on the protection of the control panel against electrostatic
discharge (ESD) can be found in the respective data sheet
(Table 1 "Required and supplementary documentation" on page 4).
▶ Remove the packaging from the control panel.
▶ Check the control panel for transport damage and completeness, see chapter 4
"Scope of delivery" on page 13.
▶ Dispose of the packaging in accordance with the regulations in your country.
7�2 Installation conditions
The installation position and location of the control panel essentially determine
the procedures for installation and commissioning.
▶ Do not install the control panel near parts which generate considerable heat
(e.g. exhaust system).
▶ Lines are to be routed with sufficient distance from hot or moving vehicle parts.
▶ Radio equipment and mobile telephones must not be used in the driver's cab
without a suitable antenna or near the control electronics.
▶ A sufficient distance to radio systems must be maintained.
▶ Before electric welding and painting operations, the control panel must be
diskonnected from the power supply and the control panel connector must be
removed.
▶ Cables/wires must be sealed individually to prevent water from entering
the control panel.
7�3 Assembling control panels
7�3�1 Preparation
1. Check the material number on the sticker of the packaging unit or the control
panel to make sure that the correct control panel is used, see chapter 4
"Scope of delivery" on page 13.
2. Compare the material number with the details in the order confirmation.
If the material number of the control panel does not match the one in the order
confirmation, contact your local contact person for clarification. You can find
their contact information at
https://addresses.boschrexroth.com