Standards; Standards Used - Bosch Rexroth VAM 10.2 Project Planning Manual

Machine control panels
Table of Contents

Advertisement

DOK-SUPPL*-VAM*XX.2***-PR03-EN-P
Rexroth IndraControl VAM 10.2/40.2 Machine Control Panels
5.7

Standards

5.7.1

Standards used

Ambient
In operation
conditions
Air pressure
Up to 3,000 m
above sea level acc.
to EN 61131-2
Mechanical
Max. vibration:
strength
Frequency range:
10...150 Hz
Excursion: 0.075
mm at 10 Hz to 57
Hz
Acceleration: 1 g at
57 Hz to 150 Hz
Acc. to EN
60068-2-6
Contamina‐
2
tion level
Overvoltage
2
category
Tab. 5-10:
Ambient conditions
The system components of the VAM 10.2/VAM 40.2 correspond to the follow‐
ing standards:
Standard
Significance
EN 60 204-1
Safety of machinery - Electrical equipment of machines
EN 60 61000-6-4
Generic standards - Emission standard (industrial environ‐
ments)
EN 60 61000-6-2
Generic standards – Noise immunity (industrial environ‐
ments)
EN 61558-2-6
Transformer for 24 V power supply unit, safe separation
EN 60664-1
Overvoltage category II
EN 61 131-2
24 V output requirements
EN 61 131-2
24 V current supply requirements
EN 60950
Clearances and creepage distances office (environment)
and power units
ISO 13850
Safety of machinery - E-STOP - Principles for design
EN 60 529
Degrees of protection (including housings and installation
compartments)
EN 60 068-2-6
Vibration test
EN 60068-2-27
Shock test
EN 60721-3-3
Classification of ambient conditions
Bosch Rexroth AG
Transport
Storage
Up to 3,000 m above
Up to 3,000 m above
sea level acc. to
sea level acc. to
EN 61131-2
EN 61131-2
Max. shock:
Max. shock:
15 g 11 ms
15 g 11 ms
acc. to EN 60068-2-27,
acc. to EN
60068-2-27,
No malfunction
No malfunction
2
2
19/69
Technical data

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth vam 40.2R911170770R911170772