Ambient Conditions; Standards; Used Standards - Bosch Rexroth IndraControl VDP 08.3 Manual

Operator terminal
Table of Contents

Advertisement

22/81
Bosch Rexroth AG
Technical Data
4.3

Ambient Conditions

In operation
Max. ambient temper‐
+5 °C up to +45 °C
ature
Max. temperature gra‐
Temporal temperature changes
dient
up to 3 K per minute
Humidity
Min. relative humidity: 5 %
Max. relative humidity: 85%
Min. absolute humidity: 1 g/m
Max. absolute humidity: 25 g/m
Condensation not allowed
Corresponds to climatic class
3K3 acc. to EN 60721-3-3
Air pressure
Up to 3000 m above sea level
acc. to EN 61131-2
Mechanical strength
Max. vibration:
Frequency range: 10 to 150 Hz
Excursion: 0.075 mm for 10 to 57
Hz
Acceleration: 1 g for 57 to 150 Hz
acc. to EN 600068-2-6
Degree of pollution
2
Overvoltage category 2
4.4

Standards

4.4.1

Used Standards

System components - EN stand‐
Transport
-20 °C up to +60 °C
Temporal temperature changes
up to 3 K per minute
Min. relative humidity: 5 %
Max. relative humidity: 75%
3
Min. absolute humidity: 1 g/m
3
Max. absolute humidity: 25 g/m
Condensation not allowed
Corresponds to climatic class
2K2 acc. to EN 60721-3-2
Up to 3000 m above sea level
acc. to EN 61131-2
Max. shock:
15 g 11 ms
acc. to EN 60068-2-27
No breakdown of the function
2
-
Fig.4-3:
Ambient Conditions
The front panels comply with the FT 1) quality guideline, issue November 2009,
category 1.
The system components of the Operator Terminals correspond to the following
ards
standards:
Standard
EN 60 204-1
EN 61 000-6-4
EN 61 000-6-2
EN 61 558-2-6
FT = Fachgemeinschaft Tastaturen, a professional association of keypad manufac‐
1)
turers in Germany
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Storage
-20 °C up to +60 °C
Temporal temperature changes
up to 3 K per minute
Min. relative humidity: 5 %
Max. relative humidity: 85%
3
Min. absolute humidity: 1 g/m
3
Max. absolute humidity: 25 g/m
Condensation not allowed
Corresponds to climatic class
1K2 acc. to EN 60721-3-1
Up to 3000 m above sea level
acc. to EN 61131-2
Max. shock:
15 g 11 ms
acc. to EN 60068-2-27
No breakdown of the function
2
-
Meaning
Electrical equipment of machines
Generic standard, emitted interference (industrial envi‐
ronment)
Generic standard, noise immunity (industrial environ‐
ment)
Transformer for 24 V power supply unit, protective sepa‐
ration
3
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indracontrol vdp 40.3

Table of Contents