Cooling system
•
Apply a large quantity of grease to the
sides of the H2O pump so that it is eas-
ier to insert the cover.
CAUTION
WHEN MOUNTING THE COVER, MAKE SURE THAT IT IS
INSERTED PERPENDICULARLY TO THE GUARD, APPLY-
ING EVEN PRESSURE OVER THE ENTIRE SURFACE IN
ORDER TO AVOID DAMAGING THE O-RINGS.
Removing the radiator
•
Remove the fuel tank.
•
Locate a suitable recipient for collect-
ing the coolant.
•
Remove the filler cap.
•
Access the left hand side of the motor-
cycle, loosen the clamp and move it to
one side so that it is possible to dis-
connect the tube and drain the coolant.
•
Loosen the clamp and remove it, then
disconnect the tube from the radiator,
collecting the coolant in the recipient.
COOL SYS - 396