Electrical system
P1606 Hardware and software incompatibility
Error cause
•
Incorrect engine control unit mapping
This error is indicated by lighting up in a fixed manner the general warning light.
Troubleshooting
•
Call the Help Desk
NOTE
THIS ERROR DETERMINES THE ENGINE STOP AN THE DEACTIVATION OF THE STARTER MO-
TOR.
P1607 Saved data file (for safety reasons)
Electrical diagnosis:
•
Filled
Error cause
•
This indication appears only if the Level 2 safety has reset the engine (C gravity).
The instrument panel does not indicate the presence of this error even in the ATT status
Troubleshooting
•
Perform the troubleshooting for the other detected errors.
P1650 Engine events configuration Checksum calculation error
Error cause:
•
Corrupt Flash-eeprom (hardware problem).
•
Upload (e.g. in service) of an incompatible software version, therefore missing the reference
check-sum.
This error is indicated by lighting up in a fixed manner the general warning light.
Troubleshooting:
•
Call the Help Desk.
Errori di errata configurazione
P1901 Ax acceleration sensor plausibility
Functional diagnosis:
•
Incorrect control unit set up
Error cause:
Probably there is an attempt to set up the control unit with an inadequate map.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1902 Az acceleration sensor plausibility
Functional diagnosis:
ELE SYS - 130
SHIVER 900