When The Optical Connector Cleaner (Commercially Available) Is Not Available (Connectors/Cables Of Lemo) - Sony HDCU3500 Service Manual

Camera control unit
Hide thumbs Also See for HDCU3500:
Table of Contents

Advertisement

3.
While pressing the optical connector cleaner against the tip of the optical contact, rotate the optical connector
cleaner by 4 to 5 turns clockwise. Holding the optical connector cleaner at around its support facilitates to apply
the pressure.
Alignment sleeve
Optical connector cleaner
Support
Connector
Clean the tip of the optical contacts (white) using the optical connector cleaner.
Optical contact
(white)
1-5-2.
When the Optical Connector Cleaner (Commercially Available) is not
Available (Connectors/Cables of LEMO)
Clean the LEMO connectors and cables using the following procedure.
Fixtures
• Alignment sleeve remover HC-001 (for female connector)
Sony Part No. : J-6480-010-A or DCC.91.312.5LA manufactured by LEMO, or equivalent
Note
Insert the shorter nose end when removing/installing the alignment sleeve. This fixture contains shock absorber
portion. Grasp not the shock absorber portion of the remover but the handle in use.
Shock
absorber portion
Insert the shorter nose end
• Alcohol (commercially available)
• Cotton swabs (commercially available)
Note
Use a cotton swab whose diameter is about 4 mm. If a cotton swab whose diameter exceeds 5 mm is used, the
cotton swab cannot be inserted into the end of the connector and the tip of the optical contact cannot be cleaned.
HDCU3500/HDCU5500
Handle
Optical contacts (white)
1-12