Flexible Flat Cable And Coaxial Cable; Disconnecting And Connecting Flexible Flat Cable - Sony HDCU3500 Service Manual

Camera control unit
Hide thumbs Also See for HDCU3500:
Table of Contents

Advertisement

1-8.

Flexible Flat Cable and Coaxial Cable

1-8-1.

Disconnecting and Connecting Flexible Flat Cable

Note
• Be very careful not to fold flexible flat cables. Life of flexible flat cable will be significantly shortened if it is
folded.
• Each flexible flat cable has conductive side and insulated side. If the flexible flat cable is connected in the wrong
orientation of the conductive side and the insulated side, the circuit will not function.
• Insert the flexible flat cable straight.
• Check that the conductive side of the flexible flat cable is not contaminated.
Type A
Disconnecting
Flexible flat cable
Latch
A
Connector
1.
Open the latch of the connector in the direction of arrow A to unlock.
2.
Disconnect the flexible flat cable.
Connecting
Insulated side
B
1.
Insert the flexible flat cable firmly as far as it will go with the insulating surface facing front.
2.
Close the latch of the connector in the direction of arrow B to lock the flexible flat cable.
HDCU3500/HDCU5500
Flexible flat cable
Latch
Connector
1-19