Sony HDCU3500 Service Manual page 104

Camera control unit
Hide thumbs Also See for HDCU3500:
Table of Contents

Advertisement

ANALOG ADJUST
Screen display
<ANALOG ADJUST>
PROMPTER1 LEVEL : 0
PROMPTER2 LEVEL : 0
27MHz CLOCK
: 137
Description
Item
Setting Value
‐127 to 128
PROMPTER1 LEVEL
‐127 to 128
PROMPTER2 LEVEL
27MHz CLOCK
0 to 255
POWER UNIT
Screen display
<POWER UNIT>
OUTPUT
CAMERA :123.45V
1.23A
RCP
:123.45V
0.36A
VIF
:123.45V
0.36A
TX
:123.45V
0.36A
NET
:123.45V
0.36A
ENC-M
: 13.88V
3.43A
ENC-S
: 14.32V
0.00A
INPUT
POWER
:123.45V
TEMPERATURE
:555.2
CAM POWER REMOTE : NORMAL
Description
Item
Setting Value
CAMERA
RCP
VIF
TX
NET
POWER
TEMPERATURE
HDCU3500/HDCU5500
?S05 TOP
Description
Adjust the PORMPTER1 input signal level.
Adjust the PORMPTER2 input signal level.
Adjust the 27 MHz oscillation frequency.
?S06 TOP
123.45W
123.45W
123.45W
123.45W
123.45W
With HKCU-SFP50 installed
47.69W
With HKCU-REC55 installed
0.04W
Description
Display the camera power supply status, voltages, and current measurement
values.
Display the RCP power supply status.
Display the VIF-75 board power supply status.
Display the TX-167 board power supply status.
Display the NET-37 board power supply status.
Display the power unit power supply status.
Display the temperature of the power unit.