TERMINAL ASSEMBLY (1 OF 2)
1
KF-E42A10/E50A10
Install Terminal shield (p/n:2-596-920-01)
Install HPC Assy.
Use 4x16mm screw to fix HPC Assy. Use M4 Clamp on one screw
Screw p/n: 2-580-640-01
M4 Clamp p/n: 2-594-861-01
Install Conn. Assy. 1-910-015-31 and dress in M4 Clamp
Install Faston Wire Assy. 1-910-015-32
on ground tab on terminal shield.
CAUTION: Make sure Terminal Shield is installed under BOTH plastic
clips.
2
KF-E42A10/E50A10
Tool / Torque
-Phillips Screw Driver
-[4x16mm]
-13kg-cm +-1.0kg-cm
Caution Points
63