LOWER MAIN HARNESS INSTALLATION (3 OF 3)
Apply one loop around cable above ferrite core with
C-shield M3 Clamp. Reason is to hold ferrite core
steady during transportation (prevents excessive
movement).
Route wires UNDER AGA Board (on chassis assy).
Connect CN8005(10P), CN8003(40P w/ferrite core).
CAUTION: Make sure cables to not bind or pinch
between plastic PWB support peg when inserting
chassis assembly.
KF-E42A10/E50A10
9
10
KF-E42A10/E50A10
Tool / Torque
-Phillips Screw Driver
-[3x12mm]
- 7kg-cm +-1.0kg-cm
Caution Points
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)