OVERALL ASSEMBLY (3 OF 3)
9
Connect S-Master Connector (p/n:1-910-015-30) to
AGA-Bd CN8001 (15P).
CAUTION: Keep ferrite core and 11mm
purselock/bundled wire BEHIND the AGA-Bd.
KF-E42A10/E50A10
10
Connect IRIS connector (from front of Optical Block) in AGA-Bd
CN8406 (8P).
Dress both HDMI Cable (with ferrite core) and IRIS cable in angled
purselock on bottom cabinet (p/n:4-355-912-11).
CAUTION: Make sure both cable assemblies are dressed in
purselock and that purselock is CLOSED after placing wires (twist to
close).
KF-E42A10/E50A10
Tool / Torque
Caution Points
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
58