C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Note: Measurement is taken from top/side of the
opening, NOT the top/side of the fireplace.
Combustible Mantels
Note: All
measurements
in inches.
13
12
11
10
9
8
7
6
5
4
3
1
8
7
6
5
4
3
TOP OF HOOD OR FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.2 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Non-Combustible Mantels
Note: All
measurements
in inches.
11
10
9
8
7
6
9
8
TOP OF HOOD OR
FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
Heat & Glo • SL-5/5LP-IFT, SL-7/7LP-IFT, SL-9/9LP-IFT Installation Manual • 2632-980 Rev. E • 4/21
62
CEILING
16
15
14
32
17
16
15
14
13
12
11
10
9
CEILING
16
15
14
13
12
17
32
16
15
14
13
12
11
10
Combustible Mantel Legs or Wall Projections
TOP VIEW
2-7/8 IN.
MIN
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
MANTEL LEG OR WALL PROJECTIONS
Figure 10.4 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
TOP VIEW
5-7/8 IN.
MIN.
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.5 Combustible Mantel Leg or Wall Projections
(Acceptable on one side of opening)
Non-Combustible Mantel Legs or Wall Projections
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.6 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
INTERIOR WALL
1/2 IN. MIN
3 FT. MAX.
INTERIOR WALL
3 IN.MIN.
UNLIMITED
6 IN. MAX.
UNLIMITED
3 IN. MIN.