B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
Mantels - Combustible or Painted Surfaces
Note: All
measurements
in inches.
4
3
2-1/2
5
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CL)
= 35-1/2 IN. (8000CL)
Note: Measurement is taken from top of the opening,
NOT the top of the fireplace.
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible or Painted Surfaces
Mantels - Non-Combustible
Note: All
measurements
in inches.
6
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CL)
= 35-1/2 IN. (8000CL)
Note: Measurement is taken from top of the opening,
NOT the top of the fireplace.
Figure 10.4 Minimum Vertical and Maximum Horizontal
Dimensions - Non-Combustible
54
TO CEILING
18
12
11
10
32
9
8
25
7
19
6
18
5
17
16
15
14
13
12
11
10
TO CEILING
18
12
11
10
32
9
8
25
7
19
18
17
16
15
14
Heat & Glo • 6000CL-IFT, 8000CL-IFT Installation Manual • 2504-980 Rev. Q • 11/21
Mantel Legs or Wall Projections
TOP VIEW
A
FIREPLACE OPENING
MANTEL LEG OR WALL PROJECTIONS
Combustible or Painted Surfaces
A
If
minimum is ____, then
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Inches
A
62
87
Millimeters
1
2
Inches
B
25
51
Millimeters
Non-Combustible
A
If
minimum is ____, then
0 thru 6-7/16
Inches
A
0-164
Millimeters
6
Inches
B
152
Millimeters
Figure 10.5 Clearances to Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
INTERIOR WALL
B
B
maximum is_____.
113
138
164
189
3
4
5
76
102
127
B
maximum is_____.
6-7/16
164