Installation Standard Work Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
Customer:
Lot/Address:
Model (circle one): SL-5-IFT
SL-5LP-IFT
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead
to a  re or explosion. Install ONLY components and accessories approved by Hearth & Home Technologies.
Unapproved components and accessories could cause  replace to overheat.
Appliance Install
Veri ed that the chase is insulated and sealed. (Pg. 19)
Veri ed clearances to combustibles. (Pg. 17-18)
Fireplace is plum, level, square and secured. (Pg. 46)
Venting/Chimney Section 7 (Pg 47-53)
Venting con guration complies to vent diagrams.
Venting installed, locked and secured in place with proper clearance.
(Need to order separately.)
Firestops installed.
Attic insulation shield installed.
Exterior wall/Roof  ashing installed and sealed.
Terminations installed and sealed.
Electrical Section 8 (Pg 54-57)
Unswitched power (110-120 VAC) provided to the appliance.
Switch wires properly installed.
Gas Section 9 (Pg 58-60)
Proper appliance for fuel type.
Was a conversion performed?
Leak check performed and inlet pressure veri ed.
Veri ed proper air shutter setting for installation type.
Finishing Section 10 (Pg 61-64)
Combustible materials not installed in non-combustible areas.
Veri ed all clearances meet installation manual requirements.
Mantels and wall projections comply with installation manual requirements.
Appliance Setup Section 11 (Pg 65-71)
All packaging and protective materials removed (inside & outside of appliance).
Refractories, logs, media and embers installed correctly.
Glass assembly installed and secured.
Accessories installed properly.
Decorative barrier front properly installed.
(Need to order separately.)
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation.
Started appliance and veri ed no gas leaks exist.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your  le.
• That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
 = Contains updated information.
Heat & Glo • SL-5/5LP-IFT, SL-7/7LP-IFT, SL-9/9LP-IFT Installation Manual • 2632-980 Rev. E • 4/21
AT T E N T I O N I N S TA L L E R:
Follow this Standard Work Checklist
SL-7-IFT
SL-9-IFT
SL-7LP-IFT SL-9LP-IFT
(Builder / Gen. Contractor/) (Installer)
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
YES
IF NO, WHY?
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
__________________________
___________________________
___________________________
(Date)
2632-982 1/20
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-5lp-iftSl-7-iftSl-7lp-iftSl-9-iftSl-9lp-ift

Table of Contents