INSTALLATION AND OPERATION INSTRUCTIONS
MODEL: SL-550TRSI-AUE
AUSTRALIAN GAS ASSOCIATION CERTIFIED
CERTIFICATE NUMBER 5666
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.
HEAT & GLO, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044, USA, www.heatnglo.com
THIS PRODUCT MAY BE COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:
(United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495,
5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502,
6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652,
D445174, D462436; (Canada) 1297749, 2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-550TRSI-AUE

  • Page 1 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies, Inc. 20802 Kensington Blvd., Lakeville, MN 55044, USA Copyright 2008 • Printed in U.S.A. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 3: Table Of Contents

    3.2 Removal of Components for Service ............34 3.3 Parts Replacement ..................34 3.4 Adjustments and Replacement Parts ............34 3.5 Maintenance Tasks ..................35 3.6 Troubleshooting ..................36 4.0 Replacement Parts ...................37 Limited Warranty ....................40 = Contains updated information. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 4 153 mm TOP STANDOFFS FLUE COLLAR COVER PLATE HOOD DATA BADGE & LABELS DRESS GUARD ACCESS DOOR GAS CONTROLS ELECTRIC ACCESS GAS LINE ACCESS Figure 1. Diagram of SL-550TRSI-AUE Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 5: Installation Instructions

    Figure 2. Heater Dimensions, Locations, and Space At Wall Firestops Requirements Top ............75 mm Bottom ..........25 mm Sides.............25 mm For minimum clearances, see the balanced fl ue termi- nation clearance in Figure 23 and 28. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 6: Introduction

    WARNING: THIS UNIT IS NOT FOR USE WITH kPa for propane. Manifold (outlet) pressures should SOLID FUEL. be set at .8 kPa for natural gas models and 2.36 kPa for propane models. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 7 LP Gas cylinder. A fl ue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 8: Flue System Approvals And Installation

    PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP Flue system termination kits SLP SERIES DVP SERIES DVP-TVHW DVP-TRAP2 SLP-TRAP2 SLP-TVHW Figure 5. Flue Components and Terminations Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 9 13 mm TYP 319 mm DVP90ST NOTE: PIPES OVERLAP 32 mm AT EACH JOINT Figure 6. DVP-Series Balanced Flue Component Specifi cations (127 mm inner pipe / 203 mm outer pipe) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 10 SLP24 SLP48 SLP12 Note: Pipes overlap 34.93 mm at each joint. Figure 7. SLP Series Balanced Flue Component Specifi cations (102 mm inner pipe / 168 mm outer pipe) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 11 VERTICAL FLUEING 10.97 M MAXIMUM RESTRICTOR PLATE USE SLP SERIES COMPONENTS ONLY. Figure 8. Figure 9. STRAIGHT OUT HORIZONTAL FLUEING Max. Run 610 mm USE DVP-SERIES COMPONENTS ONLY. Figure 10. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 12 3' MIN. (0.91 M) 9' MAX. (2.74 M) 4' MIN. (1.22 M) 12' MAX. (3.66 M) V+H =36' MAX.(10.97 M) H= 12' MAX. (3.66 M) USE DVP-SERIES COMPONENTS ONLY. Figure 12. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 13 3' MIN.(0.91 M) 6' MAX. (1.83 M) 4' MIN.(1.22 M) 8' MAX. (2.44 M) 5' MIN.(1.52 M) 12' MAX. (3.66 M) NOTE: V + V MAX 33' (10.06 M) Figure 13. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 14 8' MAX. (2.44 M) 4' MIN. (1.22 M) 12' MAX. (3.66 M) H + H = 12' MAX. (3.66 M) V + H + H = 33' (10.06 M) MAX. Figure 14. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 15 4' MAX.(1.22 M) 3'MIN.(0.91 M) 6' MAX.(1.83 M) 4'MIN.(1.22 M) 8' MAX.(2.44 M) 5'MIN.(1.52 M) 12' MAX.(3.66 M) 12' MAX.(3.66 M) NOTE: V + V MAX. 33' (10.06 M) Figure 15. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 16 3´ MAX. (0.91 M) 8´ MAX. (2.44 M) 4´ MIN. (1.22 M) 4´ MAX. (1.22 M) 10´ MAX. (3.05 M) V+H+H =30´ MAX.(9.14 M) H = 4´MAX.(1.22 M) =10´MAX.(3.05 M) Figure 16. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 17 WARNING: FIRE RISK DO NOT RE- MOVE HEAT SHIELD. ELEVATED HEADER TEMPERATURES MAY CAUSE A FIRE. Figure 21. Remove the insulation basket and white insulation from the center fl ue pipe. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 18 Figure 24. Remove the insulation from the outer fl ue up against the appliance and over the tabs. Use two pipe. self-tapping screws to secure gasket to outer wrap. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 19 For elbows that are changing the fl ue direction, two screws minimum should be put in the outer fl ue at the joint to prevent the elbow from rotating. PROCEED TO STEP 4 (Install Support Brackets) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 20 1.5 m of horizontal run by a horizontal pipe support. To install support brackets for horizontal runs: • Place the pipe supports around the fl ue pipe. • Nail the pipe supports to the framing members. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 21 25.4 mm greater than the pipe is acceptable. Whenever a non-combustible wall is penetrated, the wall shield fi restop is only required on one side and no heat shield is necessary. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 22 • One section of the heat shield is attached to the wall shield. The other is attached to the termination cap in the same manner (see Figure 39). Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 23: Connecting The Gas Supply

    28.0 mJ/h 26.0 mJ/h • Slide the termination cap over the end of the fl ue pipe and rotate the pipe clockwise 1/4 turn. Burner Injector 2.49 mm 1.45 mm Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 24: Ignition System Wiring

    GROUND NEUTRAL BATTERY PORT PLUG IN THERMOCOUPLE ON/OFF BLOCK SWITCH (CONNECTED TO BACK OF VALVE) VALVE GAS LINE CONNECTED TO BACK OF VALVE Figure 41. Electronic Ignition Wiring Diagram Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 25: Blower

    The access hole for connecting the service wires is found on the right exterior side of the Figure 43. unit. See Figure 43 for wire connection detail. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 26: Finishing

    51 mm TOP FRONT EDGE OF FIREPLACE NON-COMBUSTIBLE STRIP FINISH MATERIAL TOP SEAL MAY BE COMBUSTIBLE JOINT - TOP AND SIDES OF UNIT SIDE SEAL JOINT 13 mm Figure 44. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 27: Installer Testing

    Once the purging is complete, the pilot and burner will light and operate as indicated in the Lighting Instructions. Subsequent lightings of the appliance will not require such purging. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 28: Log Placement

    LOG #2 (SRV347-703): Place log #2 so that its left edge sits against the left front grate corner and its right edge rests against the tab on the second grate bar. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 29 Push its left hand side back to the locating tab as the grate bar. LOG #5 (SRV540-704): Put the forked end of log #5 on the base in front of the grate, towards the center of the second bar grate. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 30 Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate bar and rest its rear on log #1 as shown. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 31: Operating Instructions

    SWITCH (CONNECTED TO AEROSOLS IN THE BACK OF VALVE) VICINITY OF THIS VALVE APPLIANCE WHILE GAS LINE CONNECTED TO IT IS IN OPERA- BACK OF VALVE TION. Figure 46. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 32: Safety And Lighting Information

    2. Remove batteries from receiver. fuel or fuel combustion. Keep burner and control compart- ment clean. See installation and operating instructions accompany- ing heater. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 33: Power Outage

    E. Keep the control compartment, logs, and burner area surround the logs clean by vacuuming or brushing at least twice a year. CAUTION: THE LOGS GET VERY HOT - HANDLE ONLY WHEN COOL. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 34: Removal Of Covers For Servicing

    2.0 OPERATING INSTRUCTIONS. A replacement part table is shown in SECTION 4.0 of this manual. PILOT BRACKET RETAINING SCREWS Figure 50. CAUTION: ALL SCREWS WHICH WERE RE- MOVED MUST BE REPLACED. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 35: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and fl ashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 36: Troubleshooting

    3. Be sure glass is tightened properly on unit, particularly on top corners. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 37: Replacement Parts

    4.0 REPLACEMENT PARTS SL-550TRSI-AUE Service Parts Service Parts Diagram Beginning Manufacturing Date: June 2006 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 38: Service Parts List

    Propane to Butane P2B-550I-AUE Natural to Propane N2P-550I-AUE Natural to Butane N2B-550I-AUE Pilot Orifi ce .0181 2098-518 Pilot Orifi ce .0121 2098-512 Additional service parts numbers appear on following page. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 39 Orifi ce P (.057C) 582-057 Orifi ce B (#55C) 582-855 Rheostat 491-510A Valve Bracket 2089-120 Rheostat Knob 100-512 Thermocouple Block 2098-146 Gas Shutoff Assembly 2098-320A Valve N 2098-130 Valve P 2098-131 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 40: Limited Warranty

    HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifi cations and prices. It also reserves the right to discontinue styles and products. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...
  • Page 41 Melbourne Jetmaster 444 Swan Street Richmond 3121 (03) 9429-5573 Perth Fireplace Corner 277 Lord Street East Perth 6000 (08) 9228-2600 Sydney Jetmaster 10 Martin Avenue Arncliff 2205 (02) 9597-7222 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08...

This manual is also suitable for:

Sl-350trsi-aue