C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Note: Measurement is taken from top of the
opening, NOT the top of the fireplace.
Combustible Mantels
COMBUSTIBLE MANTEL
1/2 IN.
THICK WALL
SHEATHING
14 IN. MIN. BOTTOM OF MANTEL
TO TOP OF APPLIANCE OPENING
Figure 10.3 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
12 IN. MAX.
APPLIANCE OPENING
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. L • 4/19
Non-combustible Mantels
1/2 IN.
THICK WALL
SHEATHING
NON-COMBUSTIBLE
NON-
COMBUSTIBLE
MANTEL
6 IN. MAX.
Figure 10.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
12 IN.MAX.
MANTEL
14 IN. MIN. BOTTOM OF MANTEL
TO TOP OF APPLIANCE OPENING
APPLIANCE OPENING
55