A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
8 in.
(203 mm)
8-1/8 in.
(206 mm)
15 in.
(381 mm)
SLP-HRC-SS
Horizontal Termination Cap
14-7/16 in.
14-7/16 in.
367 mm
Wall Thimble-Black
Figure 12.10 SLP Series Vent Components
Heat & Glo • SL-5/5LP-IFT, SL-7/7LP-IFT, SL-9/9LP-IFT Installation Manual • 2632-980 Rev. E • 4/21
(203 mm)
*5 in.
(127 mm)
SLP-TRAP
Horizontal Termination Cap
3-13/16 in.
(97 mm)
SL-2DVP
Adapter
13 in.
(330 mm)
367 mm
2-5/16 in.
59 mm
SLP-WT-BK
8 in.
Heat
Shield
Max
Effective
Length
3-15/16 in.
(101 mm)
4 in.
102 mm
5-1/16 in.
(128 mm)
12-5/8 IN.
(321 mm)
* Center of the horizontal vent pipe to
the vertical measuring surface.
Minimum
Term Cap
Effective Length
3-1/8 in.
Trap1
79 mm
5-1/4 in.
Trap2
133 mm
6-3/8 in.
163 mm
4-5/8 in.
117 mm
8-1/8 in.
206 mm
DVP-2SL
Adapter
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
12-5/8 IN.
(321 mm)
10-5/8 IN.
(270 mm)
SLP-RDS
ROOF DECK INSULATION SHIELD
Maximum
Effective Length
4-3/4 in.
121 mm
9-1/4 in.
235 mm
4-3/16 in.
106 mm
5-1/16 in.
128 mm
20 IN.
(508 mm)
81