C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 10.A.
TOP OF APPLIANCE OPENING
Figure 10.11 Location of Appliance Opening
Combustible Mantels
Note: All measurements in inches.
MAX.
6
3
1
23
20
18
MEASUREMENT FROM
TOP EDGE OPENING
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
Figure 10.12 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - MEZZO36-B and
MEZZO48-B
Heat & Glo • MEZZO36-B/ST-B, MEZZO48-B/ST-B, MEZZO60-B/ST-B, MEZZO72-B/ST-B Installation Manual • 2300-973 Rev. R • 12/18
58
TO CEILING
31
12
9
29
26
MAX.
Note: All measurements in inches.
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
Figure 10.13 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - MEZZO60-B and
MEZZO72-B
TO CEILING
9
6
31
3
30
27
24
MEASUREMENT FROM
TOP EDGE OPENING