86
C
6: C
N
D
-I
HAPTER
ONFIGURING
ETWORK
IAL
N
set user default callback_delay [seconds of delay]
CLID callback and PPP callback use the same callback delay.
Step Three:
CLID security provides an additional layer of security by rejecting calls
Configure
from remote users whose ANI does not match the CLID of any user on
CLID Security
the RAS 1500. The default setting is "off."
CLID security is a modem-level setting. You can apply the setting to
modems or modem groups.
To set CLID security for a modem:
You can only configure modems one at a time. To configure multiple
modems at the same time, use modem groups, below.
set switched interface [interface name] clid_security [on |
off]
For example,
set switched interface rm0/slot:1/mod:1 clid_security on
To set CLID security for a modem group:
set modem_group [modem group name] clid_security [on | off]
For example,
set modem_group callback clid_security on
To show the settings of a particular modem:
show interface [interface name]
The status of "CLID Security" is at the end of the list.
For example,
show interface rm0/slot:1/mod:1