216
C
13: U
HAPTER
SING
F
R
RAME
ELAY
8 Enable the user.
enable user sitea
9 Configure the Frame Relay datalink.
add datalink frame_relay interface rm0/wan:1 enabled yes
10 Configure a Frame Relay PVC and associate a user with it.
add frame_relay pvc btoa dlci 102 interface rm0/wan:1 user
sitea enabled yes
11 Save your work.
save all