Troubleshooting Power Failures

CTP Platform Does Not Power On

Problem
Solution
Related
Documentation

CTP Platform Shuts Down

Problem
Solution
Copyright © 2017, Juniper Networks, Inc.
CTP Platform Does Not Power On on page 131
CTP Platform Shuts Down on page 131
Description:
Symptoms:
Device is not receiving power.
Module's power supply has malfunctioned.
Power source cannot handle system load.
Verify that all power connections are correct.
1.
Verify that the power supply is delivering the correct voltage, current, and wattage to
2.
the device. See the system specifications for your particular CTP platform.
If the platform still does not operate, contact the Juniper Networks Technical
3.
Assistance Center (JTAC).
CTP Platform Shuts Down on page 131
Description:
Symptoms:
Temperature is too high.
Power is lost.
Verify that power connections are properly attached.
1.
Verify that device is receiving power.
2.