Access Control (cont'd)
Galaxy Dimension Installer Manual
Dual Access Cards
If a user's card number is assigned a *, then the card becomes Dual access. This means that it will not open
the door on its own; it needs another PIN or card as well. (see option 42 = Codes for programming).
Dual Focus (Card Held)
If a card has a # assigned to the number, then any card-held function will only work in conjunction with the
PIN from the same user, provided that the PIN has a # assigned also. The Dual Focus function will work in
either order, but if the card is presented first, it will simply enable the PIN to gain access to the normal menu
(see option 42 = Codes for programming).
Timed Anti-Passback
When the Timed Anti-Passback feature is enabled, it will prevent more than one use of any particular card at a
particular reader within a given time period. See option
69.2.2.6 = Access Control.MAX.Max Parameters.Anti-Passback for programming details.
A forgiveness function is available to clear all or particular antipassback restrictions in force. There are set
Anti-Passback users as defined in the following Table. If a card belonging to one of these users is swiped at a
reader, all anti-passback restriction at that reader are cleared. A manager code can authorise a forgive function
on a particular user in option 42.1 = Codes.User Codes. An engineer code can authorise a forgive function
on a particular reader in option 69.2.2.6.3 = Access Control.MAX.Max Parameters.Anti-
Passback.Forgive.