Galaxy Dimension Installer Manual

Appendix D: Event Log Messages

KEYPAD TEXT
0001 + CU-BATT
Control Unit Standby Battery Low has occurred (battery voltage below 10.5 Vd.c.).
0001 - CU-BATT
Control Unit Standby Battery Low has finished (battery voltage now above 10.5 Vd.c.).
0002 + CU-AC
Control Unit Mains (a.c.) Power Fail has occurred.
0002 - CU-AC
Control Unit Mains (a.c.) Power Fail has finished.
0003 + LID TAMP
Lid Tamper on control unit has occurred.
0003 - LID TAMP
Lid Tamper on control unit has finished.
0004 + AUX TAMP
Auxiliary Tamper on control unit has occurred.
0004 - AUX TAMP
Auxiliary Tamper on control unit has finished.
+ABORT SET
Setting process aborted
+AC+BATT
AC Fail and battery voltage low.
+ AC FAIL
AC Fail zone activated (opened) or an AC Fail on a Power Supply Unit.
AC Fail zone de-activated (closed) or an AC Fail on a Power Supply Unit has
– AC FAIL
stopped.
+ALARM EXT
Alarm extend zone activated.
ALM CAUSE
Reset of system required by entry of an alarm cause code.
ADDED
Engineer has added a module to the system.
ARC TEST
Alarm Receiving Centre Test
+ATM-1
ATM-1 zone activated.
+ATM-2
ATM-2 zone activated.
+ATM-3
ATM-3 zone activated.
+ATM-4
ATM-4 zone activated.
AUTOTEST
Automatic Test of the system via a comms module
+AUTOTIMER
Autoset timer activated.
–AUTOTIMER
Autoset timer de-activated.
BURG HIGH
High priority intruder alarm zone open
BURG LOW
Low priority intruder alarm zone open.
+BAT FUSE
Battery fuse on Power Supply Unit blown.
+ BATT LOW
Battery Low activated on Power Supply Unit.
– BATT LOW
Battery Low de-activated on Power Supply Unit.
+BEAM PAIR
Beam Pair zones activated (opened).
+BEGIN SET
Setting process started.
+ BELL FAIL
Bell Fail zone opened.
+ BELL TAMP
Bell Tamper zone activated (opened).
– BELL TAMP
Bell Tamper zone de-activated (closed).
BOOT UP
System has been started up or restarted.
CANCEL
Alarm activation Cancelled by a valid user Code (system or Group(s) still Set).
COMM FAIL
Communication Failure has occurred on a comms module.
CONFIRM
Two independent alarms.
Remote Copy of the Site (system) has occurred via Remote Servicing or the RS232
COPY SITE
Module.
CUSTOM-A
Custom-A zone activated (opened).
CUSTOM-B
Custom-B zone activated (opened).
+CU-FUSE
Control Unit Fuse trouble.
DELAY ALM
PA Delay Alarm zone activated after PA Delay timeout.
DL/SL ALM
PA Delayed Silent zone activated after PA Delay timeout.
DOOR PROP
MAX - Door left open
DR MASKED
Detector masked. Activity monitoring of zone has failed.
DUAL
Dual (Double Knock) zone activated (opened).
NOTE:
M = Mandatory. NM = Non-Mandatory
NOTE:
A plus (+) means an event has started. A negative (-) means an event has finished.
DESCRIPTION
D-1
Event Log
Trigger Event
13. Elec Status
M
20. Fault
13. Elec. Status
M
13. Elec. Status
M
20. Fault
13. Elec. Status
M
9. Tamper
M
9. Tamper
M
18. Zone restoral
9. Tamper
M
9. Tamper
M
18. Zone restoral
11. Reset
NM
13. Elec. Status
M
20. Fault
13. Elec. Status
M
20. Fault
13. Elec. status
M
20. Fault
3. 24 Hours
M
16. Log Zone
Always TR
M
9. Tamper
M
Always TR
NM
3. 24 Hours
NM
16. Log Zone
3. 24 Hours
NM
16. Log Zone
3. 24 Hours
NM
16. Log Zone
3. 24 Hours
NM
16. Log Zone
Always TR
None
NM
None
NM
2. Intrude
M
18. Zone Restoral
2. Intrude
M
18. Zone Restoral
13. Elec Status
M
20. Fault
13. Elec. status
M
20. Fault
13. Elec. status
M
20. Fault
2. Intruder
NM
None
NM
16. Log Zone
NM
9. Tamper
M
9. Tamper
M
18. Zone restoral
13. Elec. status
NM
11. Reset/Cancel
NM
20. Fault
M
2. Intruder
M
None
NM
5. Custom zones
NM
16. Log Zone
5. Custom Zones
NM
16. Log Zone
9. Tamper
13. Elec Status
M
20. Fault
1. PA/duress
M
1. PA/duress
M
4. Security
NM
15. Trouble
M
20. Fault
2. Intruder
M