Honeywell Galaxy Dimension Series Installer Manual page 103

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual
ATM User Codes
ATM ( Automatic Teller Machine) user codes work in conjunction with ATM zone types (refer to Menu
Option 52.48-51=Program Zones ATM1-4). ATM user codes cannot be used as normal user codes for
setting/unsetting etc. The following table shows the users for each Galaxy variant that are dedicated as ATM
users::
Escaping from Engineer Mode
1.
Return to the engineer banner.
2.
Enter the engineer code.
3.
Press the esc key.
The Galaxy begins the exit engineer mode procedure by checking the integrity and security of the system:
CHECKING FOR TAMPERS
operating the system for the required period (as entered in the Standby Battery parameter — refer to
option 51.37). The system then verifies that there are no tamper conditions present on the panel, the
modules or the zones.
SYSTEM MODULES
nected to the system:
If no modules have been added or removed, " NO MODULES ADDED, ESC TO CONTINUE" is
displayed. Pressing esc returns the system to the normal banner.
If modules have been removed they are reported as missing; the engineer is prompted to view the missing
modules and to remove them from the system by pressing the ; a warning is given before the module is
removed. Press the ent key to confirm the removal of the module. Once all missing modules are removed,
the Galaxy reports the previous and current number of modules connected to the system, before returning
to the normal banner.
If modules have been added, the Galaxy reports the previous and current number of modules connected
to the system, before returning to the normal banner.
If the esc key is pressed at any time during the exit engineer mode procedure, the procedure is aborted and
the Galaxy returns to the engineer mode. This return may take several seconds to complete.
Galaxy Variant
GD-48
GD-96
GD-264
GD-520
Table 6-5. ATM User codes
— the panel calculates that the standby battery connected to it is capable of
— if there are no tamper conditions the Galaxy checks the number of modules con-
42 - Codes (cont'd)
User codes
94 to 96
242 to 246
986 to 995
986 to 995
6-29