Access Control (cont'd)
Buzzer Output
This activates the buzzer on the reader to indicate card read, access granted and card rejected. The output is
open collector and can switch up to 100 mA.
LED Output
LED output 3 is used to drive a reader LED. It is open collector and can switch up to 100 mA. LED outputs
1 and 2 are not used. The LED gives a visible indication on the reader of card read and access granted.
Relay Output
This is a relay output which is activated upon any valid card read or RTE button operation in order to tempo-
rarily unlock the door. The relay can switch up to 1A @ 30V AC.
Installation and Mounting
The DCM can be supplied installed in a standard plastic RIO box or within a Power RIO box.
Mounting the RIO Box
1.
If necessary, remove the DCM PCB from the box to allow access to the screw holes.
2.
Fix the base to the mounting surface, using the screw holes provided.
3.
All cables must be brought into the enclosure base via the cable entry points. There are six cable entry
holes for the entry of alarm cables.
4.
Attach the RIO box lid with the four thread forming screws provided.
Mounting the Power RIO Box
The DCM is mounted above the control PCB on a mounting plate.
1.
Remove the screws securing the left hand control PCB to the box.
2.
Fit the four mounting pillars supplied with the kit in place of the PCB screws.
3.
Fit the mounting plate to the pillars and secure using the screws removed from the PCB.
4.
Attach the DCM to the mounting plate using the plastic clips supplied.
Wiring the Reader to the DCM
The wires from the Reader are connected to the Weigand Reader Inputs (see Figure 5-3). Refer to separate
Reader instructions for method of wiring the Reader to the DCM.
Addressing with DIP Switches
The DCM must be given a unique address before it is connected to a power supply. The DCM can be ad-
dressed with the DIP switches. The addressing works in a binary mode. The following table shows each DIP
switch with related address number. Switches 4 to 8 must be left in the off position.
Galaxy Dimension Installer Manual
5-4