69 - Access Control (cont'd)
Assigning Groups to Group Restriction
On selecting the Groups option, the groups currently allocated to the MAX are displayed. Pressing the group
number toggles the group assigned to the MAX.
Larger Galaxy panels have 32 groups; these are displayed on the MAX in blocks of eight groups, sub-divided
into A, B, C and D. Use the A or B key to move between the group blocks; press keys 1 – 8 to assign the
relevant groups in each block to the MAX.
When the required groups have been assigned to the user, press the ent key to accept the programming and
return to the previous menu level.
5 = Emergencies
This option allows each individual MAX unit to be configured to respond to fire zones in a given set of groups.
Upon the opening of a fire zone in one of the groups allocated to the MAX, the MAX will trigger the door
strike and hold the door open until the system is reset. All the MAX LEDs will light and the buzzer will sound.
Closing the fire zone will have no effect - the MAX units are treated as latched outputs and an appropriate
level reset is required, at which point they are immediately reset.
A second group map is allocated to each MAX in order to facilitate this function. This permits the existing
door control features to be completely detached from the fire escape features.
The default setting for each MAX is all groups selected. Therefore, a system, which is unchanged from the
default will open all MAX doors in response to any fire zone activation.
On selecting the Emergencies option select the groups you want allocated to the MAX for escape purposes
and accept the programming by pressing the enter key. When a fire zone is activated in any of the groups
programmed, the door controlled by the MAX will be opened.
6 = AntiPassBack
This option, when enabled, will prevent more than one use of any particular card at a particular reader within a
given time period.
A forgiveness function is available to clear all or particular antipassback restrictions in force. A manager code
can authorize a forgive function on a particular user in option 42.1 = Codes.User Codes. An engineer code
can authorize a forgive function on a particular reader.
1 = Mode
This option has three settings:
0 = Off
No antipassback restriction
1 = Soft
Access is never denied but any violations will be recorded in the event log
2 = Hard
No access will be granted for a second swipe within the antipassback period, following a valid swipe.
2 = Timeout (0-60 minutes)
This option specifies the time that the anti passback restriction lasts for. The default is 0 minutes.
3 = Forgive
This option allows the engineer to remove all anti passback restrictions for the selected MAX. Use the A>B<
keys to select the reader address the press enter to forgive.