Honeywell Galaxy Dimension Series Installer Manual page 231

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual
Pressing the # key gives 7 different displays in the following order:
1. The system status in volts and current draw are displayed.
2. The battery standby time and the battery charge time are displayed. The standby time is the estimated
time that the battery can power the panel or smart PSU if the AC power should fail. It is based on the
actual current draw and the battery size (parameter 51.36). An exclamation mark is displayed after
standby time if the battery cannot support the panel or smart PSU for the time specified in param-
eter 51.37 = Standby Time.
3. The status of the AC power and battery are displayed. Also, if available, the lowest voltage during the
last battery load test.
4. This displays the battery charging voltage and current information. The panel and Galaxy Dimension
PSU will also display the current charging state after Battery. This is either Charging or Charged.
5. This displays the battery load test. It is only available for the on-board PSU.
Pressing the ent key again initiates a system wide battery load test. This test is only available for RIO
100 and 101.
6. This displays the AUX1 volts and current draw.
7. This displays the AUX2 volts and current draw.
NOTE: The current reading for the auxilliary supply is the total current of AUX1 and AUX2. The
current display on the keypad for AUX1 or AUX2 is the combined reading of both.
5. MAX COMMS - the communication level between the Galaxy panel and the MAX/DCM readers.
6. COMM MODULES - the communication level between the Galaxy panel and the Int Telecoms, the
Int RS232, the Audio Module and Mux Modules.
Audio Module
Audio Module
Audio Module
Audio Module
Audio Module
100% CM08
100% CM08
100% CM08 V 1 . 0
100% CM08
100% CM08
To access the MUX module diagnostics press the asterisk key when the keypad display shows the diagnostics
for the audio interface. Then use the arrow key to scroll between each MUX module. To exit the menu, to
return to the other comms modules diagnostics, press the escape key once.
7. ZONES - the status of each zone can be viewed.
8. DCM ZONES - the status of each DCM zone can be viewed.
Standby Time 8h
Standby Time 8h
Standby Time 8h
Standby Time 8h
Standby Time 8h
Charge Time
Charge Time
Charge Time
Charge Time
Charge Time
Press #
V 1 . 0
V 1 . 0
V 1 . 0
V 1 . 0
61 - Diagnostics (cont'd)
4h
4h
4h
4h
4h
Audio Module
Audio Module
Audio Module
Audio Module
Audio Module
100% CM08 13.72V
100% CM08 13.72V
100% CM08 13.72V
100% CM08 13.72V
100% CM08 13.72V
6-157

Hide quick links:

Advertisement

Table of Contents
loading